BAY51-Q·À±¬·À¸¯È«ËÜÓ«¹âµÆ
ÏêϸÐÅÏ¢
BAY51-Q·À±¬·À¸¯È«ËÜÓ«¹âµÆ²úÆ·¼ò½é
-
ÊÊÓÃÓÚ±¬Õ¨ÐÔÆøÌå»·¾³1Çø¡¢2Çø£»
-
ÊÊÓÃÓÚ¿ÉȼÐÔ·Û³¾»·¾³20Çø¡¢21Çø¡¢22Çø£»
-
ÊÊÓÃÓÚ¢òA¡¢¢òB¡¢¢òC¼¶±¬Õ¨ÐÔÆøÌå»·¾³£»
-
ÊÊÓÃÓÚζÈ×é±ðΪT1~T6/T4µÄ»·¾³£»
-
ÊÊÓÃÓÚʯÓͲÉÁ¶¡¢´¢´æ¡¢»¯¹¤¡¢Ò½Ò©¡¢·ÄÖ¯¡¢Ó¡È¾¡¢¾ü¹¤¼°¾üÊÂÉèÊ©µÈ±¬Õ¨ÐÔΣÏÕ»·¾³¡£
-
¸ù¾ÝÍâ¿Ç²ÄÖʲ»Í¬ÓоÛ̼ºÏ½ðºÍSMCÁ½ÖÖ²úÆ·¿ÉÑ¡¡£
-
Applicable to explosive gas environment zone 1, zone 2;
Can be used in flammable dust environment 20, zone 21, zone 22 zone;
Applied to A, B, C grade II II in explosive gas environment;
Apply to the temperature required for T1 ~ T6 / T4 environment;
Applicable to the petroleum production and refining, storage, chemical, medicine, textile, printing and dyeing, military and military facilities in explosive environment.
According to the housing materials of different poly carbon alloy and SMC two optional products.
BAY51-Q·À±¬·À¸¯È«ËÜÓ«¹âµÆ²úÆ·Ìصã
-
¿ÇÌå²ÉÓýø¿Ú¾Û̼ºÏ½ð×¢ËÜ£¬Ç¿¶È¸ß¡¢Äͳå»÷¡¢Ä͸¯Ê´¡¢ÄÍÈÈÐÔ¡¢Äͺ®ÐԺã»
-
µÆÕÖ²ÉÓþÛ̼Ëáõ¥×¢Éä³ÉÐÍ£¬Í¶¹âÂʸߡ¢³ÐÊܳå»÷ÄÜÁ¦Ç¿£»
-
µÆ¾ß²ÉÓöÀÌصÄË«ÉàʽÉè¼ÆÃÜ·âÌõ½á¹¹£¬¾ßÓнÏÇ¿µÄ·ÀË®¡¢·À³¾ÐÔÄÜ£»
-
¶ÀÌصÄË«Å×ÎïÃæÉè¼Æ·´¹âÕÖ£¬Ê¹µÆ¾ß¹âЧ´ó·ùÌá¸ß£»
-
½ÓÏß·½±ã£¬Ö»Ðè´ò¿ªµÆÕÖ£¬¼´¿ÉÖ±½Ó½ÓÏߣ»
-
²ÉÓÿ¨½ôʽ½ÓÏ߶Ë×Ó£¬°²×°·½±ã¿ì½Ý£»
-
ÅäÓÃ*Æ·ÅÆÓ«¹âµÆ¹Ü£¬ÊÙÃü³¤¡¢¹âЧ¸ß£»
-
Åä×°ÎÒ¹«Ë¾ÌØÖƵķÀ±¬µç×ÓÕòÁ÷Æ÷£»
-
ÄÚÖøôÀ뿪¹Ø£¬µ±²úÆ·´ó¿¬Ê±×Ô¶¯ÇжϵçÔ´£¬Ìá¸ß²úÆ·µÄ°²È«ÐÔÄÜ£»
-
´øÓ¦¼±×°ÖõÄÓ«¹âµÆÔÚ¹©µçÏß·ʧµçʱ£¬×Ô¶¯Çл»µ½Ó¦¼±ÕÕÃ÷״̬£»
-
Ó¦¼±×°ÖÃÄÚÓÐÌرðÉè¼ÆµÄ¹ý³ä¡¢¹ý·Å±£»¤µç·£»
-
¸Ö¹Ü»òµçÀ²¼Ïß¡£
-
The shell adopts the imported polycarbonate alloy injection molding, high strength, impact resistance, corrosion resistance, heat resistance, cold resistance;
The lampshade adopts polycarbonate injection molding, cast light rate is high, strong impact bearing ability;
The lamp adopts unique double tongue type design of seal structure, with strong waterproof, dustproof performance;
The unique design of the double paraboloid reflector, so that the lamp light efficiency increase;
Convenient wiring, simply open the shade, can direct wiring;
The clamping type connecting terminal, convenient and quick installation;
With the well-known brands of fluorescent tube, long life, high luminous efficiency;
With my company 's special explosion-proof electronic ballast;
Isolating switch, when the product is large when the power supply is automatically cut off, to improve the safety performance of the product;
The emergency device of fluorescent lamp power supply line in the power failure, automatically switch to the state of emergency lighting;
Emergency device within a specially designed overcharge, overdischarge protection circuit;
Steelpipe and cable wiring.
BAY51-Q·À±¬·À¸¯È«ËÜÓ«¹âµÆ¼¼Êõ²ÎÊý
-
Ö´Ðбê×¼£ºGB 3836.1¡¢GB 3836.2¡¢GB 3836.3¡¢GB 12476.1¡¢IEC60079
-
·À±¬±êÖ¾Exd¢òCT4¡¢DIP A20 TA,T6
-
¶î¶¨µçѹ£ºAC 220V
-
µÆ×ù¹æ¸ñ£ºG13¡¢G5
-
Åä×°¹âÔ´£ºT8Ë«½ÅÓ«¹âµÆ¹Ü(1 36W¡¢2 36W) T5Ë«½ÅÓ«¹âµÆ¹Ü(1 28W¡¢2 28W)
-
µç³Ø³äµçʱ¼ä£º≤24h
-
Ó¦¼±Æð¶¯Ê±¼ä£º≤0.3s
-
Ó¦¼±ÕÕÃ÷ʱ¼ä£º90min
-
·À»¤µÈ¼¶£ºIP65
-
·À¸¯µÈ¼¶£ºWF2
-
ÒýÈë¿Ú¹æ¸ñ£º3-G3/4"
-
ÊÊÓõçÀÂÍ⾶£ºφ9mm~φ14mm
-
Executive standard: GB 3836.1, GB 3836.2, GB 3836.3, GB 12476.1, IEC60079
Explosion proof mark Exd II CT4, DIP A20 TA, T6
Rated voltage: AC 220V
Lamp socket specifications: G13, G5
Equipped with light source: T8 feet fluorescent lamp (1 36W, 2 36W ) T5 double fluorescent lamp (1 28W, 2 28W )
Battery charge time: < 24h
Emergency starting time: < 0.3s
Emergency lighting time: 90min
Protection grade: IP65
Anticorrosion grade: WF2
Introduction of export specifications: 3-G3 / 4"
Application of outer diameter of cable: diameter of 9mm ~ 14mm diameter
BAY51-Q·À±¬·À¸¯È«ËÜÓ«¹âµÆ°²×°Óëά»¤
-
Ö»Ðè´ò¿ª¿ÇÌåÍⲿµÄ¿¨¿Û£¬´ó¿¬µÆÕÖ¼´¿É½ÓÏߣ»
-
ÒýÈë×°ÖõÄÃÜ·âȦӦȷ±£¿É¿¿Ñ¹Àβ¢½«µçÀ¼нô£»
-
µÆ¾ßÉ϶àÓ಻ÓõÄÒýÈë¿ÚÇë²ÉÓö°åºÍѹ½ôÂÝĸ¿É¿¿ÃÜ·âÈ·±£·À±¬ÐÔÄܺͷÀ»¤µÈ¼¶ÄÜ£»
-
µÆ¾ßͶÈëʹÓÃÇ°±ØÐ뽫ÄÚÍâ½ÓµØÀι̡¢¿É¿¿µØ½ÓÈëÓû§ÏÖ³¡½ÓµØϵͳ£»
-
°²×°¼°Î¬»¤µÆ¾ßʱ£¬ÑϽû´øµç´ò¿ª£»
-
¶¨ÆÚ¼ì²éÃÜ·âÃ棬Èç·¢ÏÖÆäÀÏ»¯Ó¦¼°Ê±¸ü»»£»
-
Ó«¹âµÆµÄÓ¦¼±µç³Ø³ö³§Ê±´¦ÓÚ·Å¿Õ״̬£¬Óû§Ê¹ÓÃÇ°Ó¦Ïȳä×ãµç·½¿ÉÕý³£Ê¹Óá£
-
Just open the shell buckle, block shade can connection;
Introducing device of the ring should be pressed firmly and ensure reliable cable clamp;
Lamps spare inlet use blocking plate and a compression nut sealing to ensure reliable explosion-proof performance and protection grade can;
Lamps used to be inside a solid grounding, reliable access to the user site grounding system;
Installation and maintenance of lighting, strictly charged to open;
Regularly check the sealing surface, where it is found that the aging should be replaced;
Fluorescent lamp emergency battery factory in the empty state, before the user is used should be sufficient power can be normal use.